HE IMPLANTABLE CARDIOVERTER DEFIBRILLATOR, or T"lCD," is arguably the most technologically challenging type of therapy that physicians utilize today. At the same time, engineers who design ICDs are being called upon by clinicians to extend even further the technological envelope in quest of building the "ideal" device. To the extent, however, that physicians who utilize ICDs are not sufficiently comfortable with or familiar with the engineering principles that guide ICD function, the full clinical potential of even an ideal device will not be realized. In comple mentary fashion, engineers…mehr
HE IMPLANTABLE CARDIOVERTER DEFIBRILLATOR, or T"lCD," is arguably the most technologically challenging type of therapy that physicians utilize today. At the same time, engineers who design ICDs are being called upon by clinicians to extend even further the technological envelope in quest of building the "ideal" device. To the extent, however, that physicians who utilize ICDs are not sufficiently comfortable with or familiar with the engineering principles that guide ICD function, the full clinical potential of even an ideal device will not be realized. In comple mentary fashion, engineers require as full an appreciation as possi ble of the real world "boundary conditions" and clinical impact of various ICD features, if the latter are truly to be perfected. This book is intended to serve as an educational tool to foster mutual understanding and communication among physicians, engineers, and other professionals involved in ICD therapy, with the ultimate purpose of enhancing patientcare. The highly varied backgrounds of such a diverse audience posed obvious challenges in the preparation of this volume. Given the overwhelmingly greater involvement of clinicians in the day-to day management and follow-up of ICD recipients, we gave high priority to the presentation of oftentimes complex yet relevant engi neering concepts in a manner that could be understandable to most clinicians.Hinweis: Dieser Artikel kann nur an eine deutsche Lieferadresse ausgeliefert werden.
Preface. 1. Sudden Cardiac Death; M. Akhtar, et al. 2. History of the ICD; W.S. Staewen, M.M. Mower. 3. The Electrophysiological Effects of Defibrillation Shocks; S.M. Dillon. 4. Defining the Defibrillation Dosage; M.W. Kroll, et al. 5. The Defibrillation Threshold; I. Singer, D. Lang. 6. Pathways for Defibrillation Current; M.J. Kallok. 7. The Defibrillation Waveform; S.M. Blanchard, et al. 8. The System; C.G.J. Supino. 9. Leads for the ICD; R.S. Nelson, et al. 10. The Battery; C.F. Holmes. 11. The High Voltage Capacitor; J.B. Ennis, M.W. Kroll. 12. The Pulse Generator; R.S. Nelson. 13. High Power Circuitry; S.M. Bach, P. Monroe. 14. The Amplifier: Sensing the Depolarization; D.A. Brumwell, et al. 15. Tachyarrhythmia Detection; S.M. Bach, et al. 16. Anti-Tachycardia Pacing and Cardioversion; M.L. Hardage, M.B. Sweeney. 17. Implantation: Pre-Operative Evaluation to Discharge; W. Grimm, F.E. Marchlinski. 18. ICD Infection Avoidance: Science, Art, Discipline; R.B. Shepard, A.E. Epstein. 19. Safety Margins for Sensing and Detection: Programming Tradeoffs; W. Olson. 20. Patient Followup Systems; T.P. Adams. 21. Troubleshooting Suspected ICD Malfunction; M.E. Rosenthal, et al. 22. Clinical Results; R.N. Fogoros. 23. Sudden Death Despite ICD Therapy; M.H. Lehmann, et al. 24. Future Clinical Challenges; M.H. Lehmann, M.W. Kroll. Glossary. Index.
Preface. 1. Sudden Cardiac Death; M. Akhtar, et al. 2. History of the ICD; W.S. Staewen, M.M. Mower. 3. The Electrophysiological Effects of Defibrillation Shocks; S.M. Dillon. 4. Defining the Defibrillation Dosage; M.W. Kroll, et al. 5. The Defibrillation Threshold; I. Singer, D. Lang. 6. Pathways for Defibrillation Current; M.J. Kallok. 7. The Defibrillation Waveform; S.M. Blanchard, et al. 8. The System; C.G.J. Supino. 9. Leads for the ICD; R.S. Nelson, et al. 10. The Battery; C.F. Holmes. 11. The High Voltage Capacitor; J.B. Ennis, M.W. Kroll. 12. The Pulse Generator; R.S. Nelson. 13. High Power Circuitry; S.M. Bach, P. Monroe. 14. The Amplifier: Sensing the Depolarization; D.A. Brumwell, et al. 15. Tachyarrhythmia Detection; S.M. Bach, et al. 16. Anti-Tachycardia Pacing and Cardioversion; M.L. Hardage, M.B. Sweeney. 17. Implantation: Pre-Operative Evaluation to Discharge; W. Grimm, F.E. Marchlinski. 18. ICD Infection Avoidance: Science, Art, Discipline; R.B. Shepard, A.E. Epstein. 19. Safety Margins for Sensing and Detection: Programming Tradeoffs; W. Olson. 20. Patient Followup Systems; T.P. Adams. 21. Troubleshooting Suspected ICD Malfunction; M.E. Rosenthal, et al. 22. Clinical Results; R.N. Fogoros. 23. Sudden Death Despite ICD Therapy; M.H. Lehmann, et al. 24. Future Clinical Challenges; M.H. Lehmann, M.W. Kroll. Glossary. Index.
Es gelten unsere Allgemeinen Geschäftsbedingungen: www.buecher.de/agb
Impressum
www.buecher.de ist ein Internetauftritt der buecher.de internetstores GmbH
Geschäftsführung: Monica Sawhney | Roland Kölbl | Günter Hilger
Sitz der Gesellschaft: Batheyer Straße 115 - 117, 58099 Hagen
Postanschrift: Bürgermeister-Wegele-Str. 12, 86167 Augsburg
Amtsgericht Hagen HRB 13257
Steuernummer: 321/5800/1497
USt-IdNr: DE450055826
Wir verwenden Cookies und ähnliche Techniken, um unsere Website für Sie optimal zu gestalten und Ihr Nutzererlebnis fortlaufend zu verbessern. Ihre Einwilligung durch Klicken auf „Alle Cookies akzeptieren“ können Sie jederzeit widerrufen oder anpassen. Bei „Nur notwendige Cookies“ werden die eingesetzten Techniken, mit Ausnahme derer, die für den Betrieb der Seite unerlässlich sind, nicht aktiviert. Um mehr zu erfahren, lesen Sie bitte unsere Datenschutzerklärung.
Notwendige Cookies ermöglichen die Grundfunktionen einer Website (z. B. Seitennavigation). Sie können nicht deaktiviert werden, da eine technische Notwendigkeit besteht.
Funktionale Cookies sorgen für ein komfortables Nutzererlebnis und speichern z. B. ob Sie eingeloggt bleiben möchten. Diese Arten von Cookies dienen der „Wiedererkennung“, wenn Sie unsere Website besuchen.
Wir nutzen Marketing Cookies, um die Relevanz unserer Seiten und der darauf gezeigten Werbung für Sie zu erhöhen und auf Ihre Interessen abzustimmen. Zu diesem Zweck teilen wir die Daten auch mit Drittanbietern.